Error code-JCHUpdated 3 years ago

Factory-JCH

  •  Controller mode(M9):

 

Manual Reset

  • 1. Press and hold both ⬇️ and ⬆️ simultaneously for 7 seconds until the controller displays "RSt", release both buttons.
  • 2. Press and hold both ⬇️ and ⬆️ simultaneously for 7 seconds until the controller displays the desk's current height,
  • 3. Release both buttons to complete the reset.

 Note: When the controller is displaying "RSt", press and hold both the ⬇️ and the ⬆️ simultaneously
 for 10 seconds until the desk reaches its lowest height and displays its current height.

  • · Error code and troubleshooting:

         *If solution 1 is not implemented, then solution 2 is implemented, and if solution 2 is still not implemented, then solution 3 is implemented.

Garbled code

RST

HOT

F01

F03

Display Error

 

 

 

 

Gorgias Reply Template

【升降故障】Fezibo JCH MDW-乱码-重置-Error Codes-Reset RST/ASR/rst/AST/R5T/rST

【升降故障】Fezibo JCH MDW-乱码-HOT
【升降故障】Fezibo JCH 单电机-乱码-重置 Error Codes-Reset F01/F02/F03/F04

【升降故障】Fezibo JCH 单电机-乱码-重置 Error Codes-Reset F01/F02/F03/F04

Code meaning

The controller cannot find the original starting point, indicating that a mechanical reset is required

Controller overheating protection

Overload during lifting and lowering

Motor signal abnormal, enter a protection program

Solution 1

Manual reset

Power off and leave for 18 minutes more

1. Remove obstructions from the table and under the table

2. Check that the table legs are not stuck

3. Mechanical reset (Reset)

1. Re-plug the table leg and hand control cable to ensure proper connection                       

2. Manual reset

Solution 2

If converted to other garbled codes

Refer to other messy code handling solutions

-

Replenishing generator table legs

Replacement hand controls

Solution 3

-

-

-

Replenishing generator table legs

 

  • Controller mode 2 (M6):


  • Manual Reset

       1. Press and hold the “Down” key for 5 seconds, and the digital display shows “RST”. 

       2. Release the key and then press and hold the “Down” key to reset.

  • Error code and troubleshooting:

          *If solution 1 is not implemented, then solution 2 is implemented, and if solution 2 is still not implemented, then solution 3 is implemented.

Garbled code

RES/RSTHOTE07

Display Error




Gorgias Reply Template

【升降故障】JCH M6 手控器复位(RST、AST、E07)JCH M6 Controller Troubleshooting
-【升降故障】JCH M6 手控器复位(RST、AST、E07)JCH M6 Controller Troubleshooting

Code meaning

The controller cannot find the original starting point, indicating that a mechanical reset is required

Controller overheating protection


Motor signal is abnormal, enter a protection program


Solution 1

Manual reset

Power off and leave for 20 minutes more

1. Re-plug the table leg and hand control cable to ensure proper connection                      2. Manual reset

Solution 2

If converted to other garbled codes

Refer to other messy code handling solutions

-

Replacement hand controls

Solution 3

--

Replenishing generator table legs


  • Controller mode 3 (H1):


  • Manual Reset

      1. Press and hold the “Down” key for 5 seconds, and the digital display shows “RST”. 

       2. Release the key and then press and hold the “Down” key to reset.

  • Error code and troubleshooting:

          *If solution 1 is not implemented, then solution 2 is implemented, and if solution 2 is still not implemented, then solution 3 is implemented.

Garbled code

RSTHOTE07

Display Error




Gorgias Reply Template

【升降故障】JCH M6 手控器复位(RST、AST、E07)JCH M6 Controller Troubleshooting
-【升降故障】JCH M6 手控器复位(RST、AST、E07)JCH M6 Controller Troubleshooting

Code meaning

The controller cannot find the original starting point, indicating that a mechanical reset is required

Controller overheating protection

Motor signal is abnormal, enter a protection program

Solution 1

Manual reset

Power off and leave for 20 minutes more

1. Re-plug the table leg and hand control cable to ensure proper connection                      2. Manual reset

Solution 2

If converted to other garbled codes

Refer to other messy code handling solutions

-

Replacement hand controls

Solution 3

--

Replenishing generator table legs

Was this article helpful?