Error Code-DWKUpdated 3 years ago
Factory-DWK
Controller:
Manual Reset
Pressing on ⬇️ button NON-Releasing for at least 6-10 seconds, UNTIL the display shifts to “E-1/rES”.
Followed by release, press again on the ⬇️ button until the read of the lowest height is shown on the display.
- Error code and troubleshooting:
*Implementation of solution 1 is ineffective, implementation of solution 2, and after implementation of solution 2 is still ineffective, implementation of solution 3.
Error code | E-1 | E-3 | E-4 | E-2 | E-5 |
Display error | | | | | |
Gorgias Reply Template | 【升降故障】Fezibo DWK-乱码-重置 Error Codes-Reset E-1/E1/error 1 | 【升降故障】Fezibo DWK-专攻 E-3/E3/error 3/ 乱码- Error Code E-3 |
| 【升降故障】下降时出现 E-2 乱码 | 【升降故障】Fezibo DWK-专攻 E-5/E5/error 5/ 乱码- Error Code E-5 |
Code Meaning | Prompt for mechanical reset | Abnormal connection of the hand control/control box to the table leg | Detected (dual motor) inconsistency in height between the two table legs | Bounce protection activated when blocked in operation | Abnormal communication between the hand control and the table leg |
Solution1 | Mechanical reset (Reset) | 1. Stand for 20 minutes or more with power off 2. Check the wiring & interface of the table leg cable, hand control connection cable and extension cable --If any damage is found, replace the corresponding parts directly 3. Reconnect all wiring and perform a manual reset | Mechanical reset (Reset) | 1. Remove obstructions from the table and under the table (pay attention to power cables and extension cords interfering) 2. Manual reset | 1. Stand for more than 20 minutes without power 2. Reconnect all wiring and reset mechanically (Reset) |
Solution2 | 1. If it changes to other fault codes, refer to other fault code solutions
2. If E-1 remains unchanged --Replacement of hand control/control box | 1. The table leg does not move - reissue the hand control 2. One-sided lifting occurs - ask the customer to cross-check (swapping) and reissue the hand control or table leg according to the cross-check result | Ask the customer to cross-check (swapping) Re-issue hand controls or table legs based on cross-validation results | 1. Adjust the collision sensitivity value, (range 1 to 30) up from the existing one. (DWK sensitivity adjustment link) 2. Manual reset 3. If it becomes other fault codes, refer to other fault code solutions | Replace controller |
Solution 3 | - | Resend generator column | - | - | Resend generator column |