Lift noise

 

1. Definition

 

It is a noise during the lifting process, which is >50 dB (about the level of a normal conversation) according to current product implementation standards.

 

A "click" from the hand control at the moment of start-up, or the sound of the motor during normal lifting and lowering are not part of the noise category.

 

2. Processing logic

 

  • ① locate the source of the noise → ② analyse the cause of the noise → ③ provide a solution

 

Sources of noise

Cause of occurrence

Solutions

Remarks

Hand controller

Internal short circuit

Replacement of hand controls

Keeps rattling after power on

Table leg motors

Loose motor

1. Reinforce the motor fixing screws

2. Replace the motor table legs

3. Replace the motor (HEZ glass table)

Commonly found in single motor products, with occasional motor vibration

Table legs

Broken internal gears/insufficiently oiled inner tubes

Replace the corresponding table leg

/

Drive rod connection

Drive rod not connected properly

Reconnecting the drive rod

Abnormal rotation of common drive rods

 

 

 

3. Common Gorgias templates

 

【升降故障】JCH-升降 噪音-单电机

【升降故障】HEZ-升降 噪音-单电机

【升降故障】DWK-升降 噪音-双电机

【升降故障】DWK-升降 噪音-单电机