All articles

Solutions - Cloumns Out of SyncUpdated 3 years ago

Columns Out of Sync

 

1. Definition

 

When lowered to its lowest point, the two legs are not at the same height, usually confirmed by the height of the exposed part of the inner tube, which does not disappear completely under normal circumstances.

 

Other common descriptions include failure to lower to the lowest point, inconsistent leg heights, out-of-sync lifts, tilting from side to side, etc.

 

2. Treatment options

 

Type

Solutions

Remarks

Single motor

Manual adjustment of the non-motor legs to the same height before assembly.

To be carried out with the drive rod removed

Twin/three motors

1. Mechanical reset.

2. Replace abnormal table legs if ineffective.

The mechanical reset method refer to individual factory fault code solutions

 

 Non-motor leg height adjustment method for single motor products.

  1. 1. Uninstall the sync rod from the desk 
  2. 2. Get it inserted into the leg with no motor first 
  3. 3. Rotate the rod until the other end of it is aligned with the right side.

 

3. Common Gorgias templates

 降故障】JCH DWK AGE 单电机 高低 Tilted Desk 调试 桌腿无法降至最低位 调节非电机侧桌腿高度